Canoga-perkins 9175 Command Reference Bedienungsanleitung Seite 722

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 790
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 721
CanogaOS Command Reference
40-51
{3 | error} Error conditions.
{4 | warning} Warning conditions.
{5 | notice} Normal but significant conditions.
{6 | information} Informational messages.
{7 | debug} Debugging messages.
Command Mode
Global configuration
Default
Logging file level is {4 | warning}
Usage
Specifying a severity-level causes messages only at that level and numerically lower levels to files.
Examples
In the following example, the user specifies that only messages of the levels error, critical, alerts, and
emergency be logged:
Switch(config)# logging level module 3
Related Commands
logging level file
40.70 logging merge
To enable the logging mergence, use the logging merge command in global configuration mode. To
restore to default value, use the no form of this command.
Command Syntax
logging merge {enable | disable | fifo-size size | timeout seconds}
no logging merge {fifo-size | timeout }
enable Enable logging mergence.
disable Disable logging mergence.
fifo-size size Set fifo size. The range is 100 to 10240.
timeout seconds Set timeout. The range is 1 to 300 seconds.
Command Mode
Global configuration
Default
Logging mergence is enabled
Usage
The logging merge command merges all the same logs into one during a specified time range. During
Seitenansicht 721