CanogaOS Command Reference
29-8
1048575.
OUT-LABEL Outgoing label, the range should be from 16 to
1048575.
Command Mode
Configure mode
Examples
In the following example, the vpls-fib-add command is used to add a static
PW for a PE in a VPLS instance:
Switch# configure terminal
Switch (config)# vpls-fib-add vpls1 peer 100.100.100.1 101 102
Related Commands
vpls-fib-delete
29.12 vpls-fib-delete
Use this command to delete a static PW for a PE in a VPLS instance.
Command Syntax
vpls-fib-delete NAME peer A.B.C.D
Syntax description
NAME Identifying string for VPLS instance.
A.B.C.D IP address of PE.
Command Mode
Configure mode
Defaults
This command has no default settings.