1-2 N525 Ethernet Termination Service Unit Management Security The N525 supports enhanced security for access to Management Functions. Four network
C-6 N525 Ethernet Termination Service Unit OAMFrameNotify = Enable OAMFramePeriodWindow = 1488095 OAMFramePeriodThreshold = 1 OAMFramePeriodNotify =
N525 Ethernet Termination Service Unit I-1 Index A add trap destination ... 3-40 user account...
I-2 N525 Ethernet Termination Service Unit security general parameters ...3-31 lockout...
CANOGA PERKINS CORPORATION 20600 Prairie Street Chatsworth, California 91311-6008 USA Phone: (818) 718-6300 FAX: (818) 718-6312 Web Site: ww
N525 Ethernet Termination Service Unit 2-1 Chapter 2 Set-up and Installation This section describes how to set up and install the N525 and its int
2-2 Ethernet Termination Service Unit Figure 5 – Bracket Attachment Detail b. Wall mounting: The N525 has slotted holes on the bottom of the unit
N525 Ethernet Termination Service Unit 2-3 Figure 7 – Bottom of N525 showing Wall Mount Holes c. Desktop/Shelf Placement: Place the N525 on a s
2-4 Ethernet Termination Service Unit Figure 8 – Ground Lug Location 5. Connecting power. The N525 is available with either AC or DC power. a. C
N525 Ethernet Termination Service Unit 2-5 Figure 10 – DC Power Connector Location Caution: To avoid damaging the fiber end-surface or connector
2-6 Ethernet Termination Service Unit Power-Up and Front Panel Functions The LEDs on the front panel show the system and port status. The STA and CF
N525 Ethernet Termination Service Unit 2-7 Table 2 – Interface Module LEDs LED Status Description Rx Modules All: UTP; 10, 100, 1000 Mbps Opt
2-8 Ethernet Termination Service Unit Remote Fault If an optical port loses the receive optical signal, it sends a Remote Fault (RMTF) signal on its
N525 Ethernet Termination Service Unit 3-1 Chapter 3 Management The N525 has three basic management interfaces, VT-100 terminal interface on the R
NOTICE Canoga Perkins has prepared this users manual for use by customers and Canoga Perkins personnel as a guide for the proper installation, operat
3-2 N525 Ethernet Termination Service Unit Setting Up SNMP Network Management Typically, the N525 communicates with CanogaView or your Network Manage
N525 Ethernet Termination Service Unit 3-3 Management User Interface The Management User Interface for the N525 provides screens for setup, monitor
3-4 N525 Ethernet Termination Service Unit User Interface Organization The user interface consists of selectable, nested screens, available in this
N525 Ethernet Termination Service Unit 3-5 System Alarms System Log Utilities 6.1. Set Date & Time 6.2. Reset Configuration To Default 6.3. C
3-6 N525 Ethernet Termination Service Unit Login and Main Menu The first screen is the Login Screen. Type your Username and press <ENTER>. Th
N525 Ethernet Termination Service Unit 3-7 System Configuration View and set values for the system information and communications parameters. 1. I
3-8 N525 Ethernet Termination Service Unit Diagnostics Used to set up loopback, latency and jitter, or PING tests and to configure and run Network Pe
N525 Ethernet Termination Service Unit 3-9 10. Max test payload (40 – 1954) This sets the maximum test packet size in bytes. The maximum packet
3-10 N525 Ethernet Termination Service Unit Port Configuration This screen has several sub menus. The following is a description of the menus: 1.
N525 Ethernet Termination Service Unit 3-11 This option allows the current account running to change their password. VT100 Baud Rate This option
N525 Ethernet Termination Service Unit iii CAUTION! This product may contain a laser diode emitter operating at a wavelength of 1300 nm - 1600 n
3-12 N525 Ethernet Termination Service Unit 802.3AH OAM The OAM work of the 802.3ah addresses three key operational issues when deploying Ethernet be
N525 Ethernet Termination Service Unit 3-13 Managing the N525 You can manage the hardware and the software for the N525, including communication ac
3-14 N525 Ethernet Termination Service Unit The configuration file consists of the header followed by a list of keywords. Each keyword represents a
N525 Ethernet Termination Service Unit 3-15 ConfigureIPAddress specifies whether the N525 will adopt or ignore the following configuration file par
3-16 N525 Ethernet Termination Service Unit To upload a configuration file from the N525 follow these steps: 1. Open a command prompt on your PC a
N525 Ethernet Termination Service Unit 3-17 6. To retrieve the configuration file, type [get N525.CFG] and press <enter> 7. To end the ftp
3-18 N525 Ethernet Termination Service Unit 4. Change the directory to BURNING by typing [cd BURNING] and press <enter> Note: that the word “B
N525 Ethernet Termination Service Unit 3-19 2. At the System Information screen, type the number for an item and press <Enter>, then type th
3-20 N525 Ethernet Termination Service Unit 2. To display information about SFP(s) on the User or Extension Port Interface Modules, press <Ctrl
N525 Ethernet Termination Service Unit 3-21 Manage the Date and Time An accurate date and time in the N525 assures accuracy for events listed in th
3-22 N525 Ethernet Termination Service Unit c. sntp Client Sync Interval (minutes): Set how often, in minutes, that the N525 tries to synchronize
N525 Ethernet Termination Service Unit 3-23 Configuring SNMP Access To set values for basic system parameters, including some parameters used by SN
3-24 N525 Ethernet Termination Service Unit f. SLIP/PPP IP Address Sets the IP Address for SLIP/PPP access. Address does not need to be configured
N525 Ethernet Termination Service Unit 3-25 Manage Traps Traps are SNMP messages that are sent to CanogaView or your Management Platform, and the N
3-26 N525 Ethernet Termination Service Unit View System Events and Traps The System Log lists all events that occurred since the last power-up or whe
N525 Ethernet Termination Service Unit 3-27 Update Software Each N525 has two flash memory banks that store software: 1. The Active Flash Memory h
3-28 N525 Ethernet Termination Service Unit 1. Access the SNMP Configuration Menu before starting the software upgrade: enter the IP Address, Subne
N525 Ethernet Termination Service Unit 3-29 5. When ready, type [Y] to initiate the file transfer. To upgrade a remote N525, or upgrade the local
3-30 N525 Ethernet Termination Service Unit To run the new software, swap banks, and reset the module. Follow these steps: 1. From the Main Menu,
N525 Ethernet Termination Service Unit 3-31 Configuring Access Security The N525 has comprehensive management access security features, including S
N525 Ethernet Termination Service Unit i Table of Contents Chapter 1 Overview...
3-32 N525 Ethernet Termination Service Unit d. Minimum Punctuation Characters Minimum number of Punctuation characters required in a valid password.
N525 Ethernet Termination Service Unit 3-33 Setting Up User Accounts You can set up an account for a user, whether another supervisor, operator, or
3-34 N525 Ethernet Termination Service Unit UI Password Expires in (days) If UI Password Expire is set to Yes; this configures how long the Password
N525 Ethernet Termination Service Unit 3-35 Configuring Host Access The N525’s SNMP Agent allows access by up to 24 Host IP addresses. Configurati
3-36 N525 Ethernet Termination Service Unit 3. The Edit Host Access Menu sets the following parameters. a. Telnet Access Telnet and SSH, Telnet Onl
N525 Ethernet Termination Service Unit 3-37 Use the Radius Client Configuration Menu to set up communications with the Radius Server to enable Radi
3-38 N525 Ethernet Termination Service Unit Syslog Client Configuration You can configure and display two server destinations for Syslog messages. I
N525 Ethernet Termination Service Unit 3-39 Trap Destination Configuration You can configure and display the destinations for Trap messages. In ad
3-40 N525 Ethernet Termination Service Unit 2. To add a destination, type [a] and press <Enter>. To edit an existing destination, type [e] an
N525 Ethernet Termination Service Unit 3-41 press <Space> to cycle through the options for these parameters: • Security Name: Enter the na
ii N525 Ethernet Termination Service Unit View Port Statistics ...
3-42 N525 Ethernet Termination Service Unit Changing Your Password Whether you have supervisor, operator, or observer access, you can update your pas
N525 Ethernet Termination Service Unit 3-43 Note: Although a user with any level of access can view this screen, you must have supervisor access t
3-44 N525 Ethernet Termination Service Unit To configure N525 ports, follow these steps: 1. From the Main Menu type [3], "Port Information,&q
N525 Ethernet Termination Service Unit 3-45 3. At the Functional Configuration Menu, type the number for an item and press <Enter>. Pressin
3-46 N525 Ethernet Termination Service Unit Check Port and Link Status The Port Information screen shows the current conditions for the N525 ports.
N525 Ethernet Termination Service Unit 3-47 Configuring VLAN Rules, Priority, and Translation The VLAN Configuration Menu provide options to config
3-48 N525 Ethernet Termination Service Unit 3. At the VLAN Rules Menu, type the number for an item and press <Enter>. Pressing <Space>
N525 Ethernet Termination Service Unit 3-49 The N525 can change VLAN Tag IDs on user packets. This is useful to avoid VLAN ID conflicts in the net
3-50 N525 Ethernet Termination Service Unit To configure VLAN Priority Bit (P-Bit) follow these steps: 1. From the Main Menu type [3], "Port In
N525 Ethernet Termination Service Unit 3-51 Configuring Port Filters Port Filters enables the N525 to filter certain management and control Etherne
N525 Ethernet Termination Service Unit iii/(iv Blank) List of Figures Figure 1 – N525 ...
3-52 N525 Ethernet Termination Service Unit View Port Statistics You can view these groups of statistics for Ethernet Packets sent through the N525:
N525 Ethernet Termination Service Unit 3-53 To display the Layer 2 Statistics, follow these steps: 1. From the Main Menu type [3], "Port Info
3-54 N525 Ethernet Termination Service Unit 4. To display the Frame Type Statistics Screen, type [T]; "Frame Type Counters" and press <
N525 Ethernet Termination Service Unit 3-55 The RMON Group 1 Statistics report shows statistics for data transfers on the N525. To view RMON Group
3-56 N525 Ethernet Termination Service Unit 3. To display the Raw information, press CTRL-T>. 4. To reset the counters, press <Ctrl-R>.
N525 Ethernet Termination Service Unit 3-57 2. At the prompt, type [1] to add a port, or type [2] to delete a port. Enter the IP Address (xxx.xxx
N525 Ethernet Termination Service Unit 4-1 Chapter 4 Maintenance and Troubleshooting General Maintenance Well-maintained components and clearly id
4-2 N525 Ethernet Termination Service Unit Measuring Transmitter Output Power To measure the output power, follow these steps: 1. Clean the connecto
N525 Ethernet Termination Service Unit 4-3 Measuring Fiber Link Attenuation Determine and record link attenuation before starting normal link traff
4-4 N525 Ethernet Termination Service Unit Use the System Alarms Screen to view alarms and faults on the N525 and its remote partner. To view alarm
N525 Ethernet Termination Service Unit 4-5 Running Diagnostics When you set up a new connection, you can verify the link connectivity using PING pr
4-6 N525 Ethernet Termination Service Unit e. DF Bit Sets if the network can fragment Test Packets. Set allows fragmentation, Clear does not allow
N525 Ethernet Termination Service Unit 4-7 PING Testing To verify network connectivity with another IP device such as another N525, an Ethernet Swi
4-8 N525 Ethernet Termination Service Unit A good connection appears similar to this with all requests returned: Pinging 216.109.112.135 with 64 byte
N525 Ethernet Termination Service Unit 4-9 Figure 23 - Local-Remote Loopback Mode • Remote-Local Mode Remote-Local Mode loops data received on t
4-10 N525 Ethernet Termination Service Unit Use the Loopback Setup Menu to display current loopback status, initiate loopbacks, and configure Address
N525 Ethernet Termination Service Unit 5-1 Chapter 5 Specifications N525 Specifications Standards: IEEE 802.3 Dimensions: 1.72" H x 12"
5-2 N525 Ethernet Termination Service Unit 9 RI Not Used, connected to GND N525 Models and Interface Modules Table 5 – N525 Models Model Descripti
N525 Ethernet Termination Service Unit 5-3 Note: All 100 Mbps CWDM wavelength tolerances: +4 to -3.5 nm 100 Mbps BIDI Interfaces 9400-154
N525 Ethernet Termination Service Unit 1-1 Chapter 1 Overview The N525 Series 10/100/1000BASE Ethernet Termination Service Unit terminates Metro
N525 Ethernet Termination Service Unit A-1/(A-2 Blank) Appendix A Warranty Information Current Warranty information is available on-line in the Cli
N525 Ethernet Termination Service Unit B-1/(B-2 Blank) Appendix B Acronym and Abbreviation List DF Do Not Fragment FPGA Field Programmable Gate A
N525 Ethernet Termination Service Unit C-1 Appendix C Configuration File Format and Fields ### WARNING - DO NOT MODIFY THIS HEADER ### CfgFileBuiltW
C-2 N525 Ethernet Termination Service Unit AuxiliaryIPAddress = 192.168.100.10 AuxiliarySubnetMask = 255.255.255.0 ModemPassword = ModemSpeed = 192
N525 Ethernet Termination Service Unit C-3 FramesOverX = 1522 UserVlanTagIn = 0 UserVlanTagIn(1) = 0 UserVlanTagIn(2) = 0 UserVlanTagIn(3) = 0 UserV
C-4 N525 Ethernet Termination Service Unit DiagnosticsTraps = Flag Error 2 SfpTraps = Flag Error 2 AuthenticationTraps = Flag Error 2 SecMinimumPass
N525 Ethernet Termination Service Unit C-5 SystemInfoCircuit2 = SystemInfoServiceCode = SystemInfoDateInService = SystemInfoDateOutService = Sys