Canoga-perkins 9171 Command Reference Bedienungsanleitung Seite 57

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 782
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 56
CanogaOS Command Reference
4-13
The threshold values are calibrated.
-------------------------------------------------------------------------------------------------------------
High Alarm High Warn Low Warn Low Alarm
Temperature Threshold Threshold Threshold Threshold
Port (Celsius) (Celsius) (Celsius) (Celsius) (Celsius)
--------- ------------------ -------------- -------------- -------------- ---------------
eth-0-21 36.25 85.00 80.00 -10.00 -15.00
--------------------------------------------------------------------------------------------------------------
High Alarm High Warn Low Warn Low Alarm
Voltage Threshold Threshold Threshold Threshold
Port (Volts) (Volts) (Volts) (Volts) (Volts)
--------- ------------------ -------------- --------------- -------------- ----------------
eth-0-21 3.34 3.80 3.60 2.97 2.80
---------------------------------------------------------------------------------------------------------------
High Alarm High Warn Low Warn Low Alarm
Current Threshold Threshold Threshold Threshold
Port (milliamperes) (mA) (mA) (mA) (mA)
--------- ------------------ --------------- --------------- --------------- ---------------
eth-0-21 7.30 79.96 69.97 0.50 0.10
----------------------------------------------------------------------------------------------------------------
Optical High Alarm High Warn Low Warn Low Alarm
Transmit Power Threshold Threshold Threshold Threshold
Port (dBm) (dBm) (dBm) (dBm) (dBm)
--------- ------------------ --------------- -------------- -------------- --------------
eth-0-21 -6.15 -1.00 -2.00 -10.50 -11.51
----------------------------------------------------------------------------------------------------------------
Optical High Alarm High Warn Low Warn Low Alarm
Receive Power Threshold Threshold Threshold Threshold
Port (dBm) (dBm) (dBm) (dBm) (dBm)
--------- -------------------- ---------------- ------------- ---------------- --------------
eth-0-21 -40.71 -- -2.00 -3.00 -19.00 -22.01
-------------------------------------------------------------------------------------------------------------
Optional status:
Rate select state: Not implemented
TX disable state: Enable
Loss of signal state: Receive optical power is too low
TX fault state: Non-faulty
Related Commands
None
4.20 static-channel-group
Use this command to aggregate the port as a member of the static-channel-group.
Seitenansicht 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 781 782

Kommentare zu diesen Handbüchern

Keine Kommentare