Canoga Perkins 2370 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Vernetzung Canoga Perkins 2370 herunter. Canoga Perkins 2370 User manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - User Manual

Model 2370 High-Speed Universal Fiber Optic Modem User Manual

Seite 2

Model 2370 Model User Manual 1-2 Figure 1. Model 2370 Modem 1.1 Modem Operation The electrical connection between the network equipment and the 2370

Seite 3 - NOTICE!

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 1-31.2 Fiber Optic Options The 2370 includes one fiber-optic transmitter and receiv

Seite 4

Model 2370 Model User Manual 1-4

Seite 5 - Table of Contents

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 2-1Chapter 2 Installation and Setup The 2370 can be installed in a UCS 1000, UCS 100

Seite 6 - List of Tables

Model 2370 Model User Manual 2-2 Caution: To avoid damaging the fiber end-surface or connector, use extreme care when installing or removing cables.

Seite 7

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 3-1Chapter 3 Electrical Data Interfaces The 2370 supports these ELIMs: • L130 Conf

Seite 8

Model 2370 Model User Manual 3-2 The V.35 interface signals follow the EIA-423 and EIA-232 protocols with minor changes, including these three end-to-

Seite 9 - Overview

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 3-33.2 P53 Interface for the L130 The L130 ELIM supports the P53 interface and exte

Seite 10 - 1.1 Modem Operation

Model 2370 Model User Manual 3-4 Use the Internal configuration when the network equipment is set for Internal Timing (see Figure 3). In this applica

Seite 11 - 1.3 Features

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 3-53.3 L131: EIA-422, DC-37 With Control Signals The L131 ELIM for EIA-449 is elec

Seite 13 - Chapter 2

Model 2370 Model User Manual 3-6 DC-37 Pin EIA-449 Signal Function Direction 18 TM Test Mode Out 19 SG Signal Ground 20 RC Receive Common 33

Seite 14

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 3-73.6 L134, L135, L136, L137: T1 and E1 The L134, L135, L136, and L137 ELIMs are

Seite 15 - Electrical Data Interfaces

Model 2370 Model User Manual 3-8 3.7 L138: EIA-422, DC-37 Without Control Signals The L138 ELIM is electrically compatible with the EIA-422A specifi

Seite 16

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 3-9• External mode: Use when the DTE provides the clock or when the 2370 is used a

Seite 17

Model 2370 Model User Manual 3-10• Slave mode: This 2370 uses the clock from the remote modem as both the TD Timing and RD Timing signals. Go to th

Seite 18

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 4-1Chapter 4 Software Management If the 2370 is in a Model 1040 enclosure or is in a

Seite 19

Model 2370 Model User Manual 4-2 4.3 Management User Interface The Management User Interface for the 2370 provides screens for setup, monitoring, and

Seite 20 - 3.5 L133: TTL, BNC

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 4-34.3.2 User Interface Organization The user interface consists of selectable, nest

Seite 21

Model 2370 Model User Manual 4-4 • To reach the chassis, and then select the 2370, follow these steps: a. Type 3, "Manage or access a specific C

Seite 22 - 3.8 L139: T88

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 4-5Table 11. System Configuration Option Definitions Menu Item Description 1) Hard

Seite 23

EdgeAccess® Universal Chassis System Model 2370 Model User Manual i CAUTION! This product may contain a laser diode operating at a wavelength of 1300n

Seite 24

Model 2370 Model User Manual 4-6 -------------------------FUNCTIONAL CONFIGURATION------------------------- Local Pri. Local Sec.

Seite 25 - Software Management

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 4-75. To return to the System Configuration menu, press <Esc>. Note: When se

Seite 26 - 4.3.1 General Screen Format

Model 2370 Model User Manual 4-8 ELIM Group Parameter Possible Values L130 with P53 Interface Type P53 Operating Mode Internal, Ext. Station, or

Seite 27

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 4-94.8 Trap Configuration Traps are messages that require management attention and a

Seite 28 - 4.5 System Configuration

Model 2370 Model User Manual 4-104.9 Alarm Output Configuration Use the Alarm Output Configuration screen to set any or all alarms to Major, Minor, o

Seite 29 - 4.7 Functional Configuration

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 4-114.10 SNMP Configuration Use the SNMP Configuration screen to view and set up the

Seite 30

Model 2370 Model User Manual 4-12Item Description 10) BOOTP Enabled Enable this if the module needs to obtain its IP address from a BOOTP server; whe

Seite 31

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 4-134.12 Diagnostics Use the Diagnostics screen to view current loopback status and

Seite 32

Model 2370 Model User Manual 4-144.13 Interface Status The Interface Status report provides information about the local and remote interface types, th

Seite 33 - 4.8 Trap Configuration

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 4-15-------------------------LINK ERROR COUNTERS----------------------------

Seite 34

Model 2370 Model User Manual ii NOTICE Canoga Perkins has prepared this users manual for use by customers and Canoga Perkins personnel as a guide for

Seite 35 - 4.10 SNMP Configuration

Model 2370 Model User Manual 4-164.15 System Alarms The System Alarms screen reports alarms and faults on the local 2370 and the remote 2370. See Fig

Seite 36 - 4.11 Host Table

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 4-174.16 Utilities Use the Utilities screen to set values for general parameters and

Seite 37 - 4.12 Diagnostics

Model 2370 Model User Manual 4-184.17 PING Use the PING Generation screen to test the connection to a specific IP address. To use the PING option, se

Seite 38 - 4.14 Link Error Counters

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 4-192. Record the numbers for the Active and Inactive Firmware for both the local a

Seite 39

Model 2370 Model User Manual 4-20

Seite 40 - 4.15 System Alarms

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 5-1Chapter 5 Troubleshooting Use the diagnostic procedures in this section to test a

Seite 41 - 4.16 Utilities

Model 2370 Model User Manual 5-2 5.1 Loopback Tests Use loopback to diagnose a fault on the optical link, either on a modem or with a cable. The 2370

Seite 42 - 4.18 Software Upgrade

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 5-3f. If the reading is incorrect, repeat the measurement with a different test cab

Seite 43

Model 2370 Model User Manual 5-4

Seite 44

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 6-1Chapter 6 Specifications 6.1 Optical Composite Error Rate: >10-12 Fiber Opti

Seite 45 - Troubleshooting

EdgeAccess® Universal Chassis System Model 2370 Model User Manual iiiTable of Contents Chapter 1 Overview...

Seite 46 - 5.1 Loopback Tests

Model 2370 Model User Manual 6-2 Interfaces Supported: RS-232D / RS-423 RS-449 CCITT V.35 TTL / BNC TwinAx 422 TwinAx MIL-STD-188-11

Seite 47 - 5.3 Fiber Optic Diagnostics

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 6-36.4 Modem Configurations 2370 Universal Fiber Optic Modem Model Description 2370-

Seite 48

Model 2370 Model User Manual 6-4 L13x ELIMs Model Interface Description L130 Configurable EIA232/423/530/P53/449/V35L131 EIA422 DC37 with control L13

Seite 49 - Specifications

EdgeAccess® Universal Chassis System Model 2370 Model User Manual A-1Appendix A Warranty Information Current Warranty information is available on-line

Seite 52

CANOGA PERKINS CORPORATION 20600 Prairie Street Chatsworth, California 91311-6008 USA Phone: (818) 718-6300 FAX: (818) 718-6312 Web Site:

Seite 53 - Warranty Information

Model 2370 Model User Manual iv 5.1 Loopback Tests...

Seite 54

EdgeAccess® Universal Chassis System Model 2370 Model User Manual vTable 4. EIA-422 Interface TwinAx Signals...

Seite 55

Model 2370 Model User Manual vi

Seite 56

EdgeAccess® Universal Chassis System Model 2370 Model User Manual 1-1Chapter 1 Overview The Model 2370 universal fiber optic modem provides full-duple

Kommentare zu diesen Handbüchern

Keine Kommentare